Cobalt VR MRI SureScan Adverse Events: FDA MAUDE Data
MEDTRONIC, INC. · Implantable Cardioverter Defibrillator (ICD) · First cleared Apr 2020
Total Reports
329
Reports (30d)
4
Active Signals
1
Open Recalls
82
What the reports describe · Claripulse analysis
Most commonly reported problems
ICD Explanted for Infection
infection, patient complications, event implantable, icd explanted, result event
2
reports
ICD Explanted with Bacteremia
infection, event patient, patient complications, icd explanted, result event
2
reports
Inappropriate Therapy for Atrial Fibrillation
fibrillation, atrial, atrial fibrillation, tachycardia, inappropriate
1
reports
Lead Integrity Alert Triggered
integrity alert, lead integrity, alert lia, lia, integrity
1
reports
Oversensing with Electromagnetic Interference
noise, icd remains, episode, patient complications, oversensing
1
reports
Inappropriate Shock for Atrial Fibrillation
fibrillation, atrial, event implantable, atrial fibrillation, tachycardia
1
reports
Problem groupings are generated by Claripulse from report narrative text. They summarize what reporters wrote, not adjudicated root cause.
Detection
Active safety signals
Regulatory
FDA recalls for this device
Oct 29, 2025 · Open, Classified
There is a potential for delayed time to high-voltage (HV) therapy should a rare sequence of events occur.
Apr 16, 2024 · Open, Classified
Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.
Apr 16, 2024 · Open, Classified
Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.
Apr 16, 2024 · Open, Classified
Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.
Apr 16, 2024 · Open, Classified
Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.
Apr 16, 2024 · Open, Classified
Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.
Keep exploring
Related devices in CRM
CAPSUREFIX Novus
MEDTRONIC, INC. · 44,929 reports
EMBLEM S-ICD
BOSTON SCIENTIFIC CORPORATION · 37,761 reports
Sprint Quattro Secure S MRI SureScan
MEDTRONIC, INC. · 37,430 reports
CapSureFix Novus MRI SureScan
MEDTRONIC, INC. · 28,090 reports
Durata
ABBOTT (ST. JUDE MEDICAL) · 19,969 reports
Quadra Assura MP
ABBOTT (ST. JUDE MEDICAL) · 10,531 reports
Want automated safety signal detection?
Claripulse monitors these devices weekly and detects anomalies using 6 statistical methods — spike, trend, changepoint, peer-outlier, and more. 1 active signal detected right now.
Get Early AccessUnderstanding this data