Cobalt XT HF Quad CRT-D MRI SureScan Adverse Events: FDA MAUDE Data
MEDTRONIC, INC. · CRT-Defibrillator (CRT-D) · First cleared Apr 2020 · 2 device variants grouped
Total Reports
2,559
Reports (30d)
44
Active Signals
0
Open Recalls
78
What the reports describe · Claripulse analysis
Most commonly reported problems
System Explanted Due to Infection
result event, explanted, defibrillator crt, crt, additional information
31
reports
RV Lead Oversensing and Pacing Inhibition
defibrillator crt, crt, lead, use, high
19
reports
Inappropriate Therapy for Atrial Tachycardia
crt, patient complications, tachycardia, ventricular tachycardia, result event
16
reports
Premature Battery Depletion
resynchronization, defibrillator crt, battery, crt, therapy defibrillator
9
reports
System Explanted Due to Pocket Infection
crt, infection, patient complications, pocket, result event
8
reports
Patient Reports Issues Post-Implant
result event, defibrillator crt, cardiac, crt, patient complications
8
reports
Problem groupings are generated by Claripulse from report narrative text. They summarize what reporters wrote, not adjudicated root cause.
Regulatory
FDA recalls for this device
Apr 16, 2024 · Open, Classified
Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.
Apr 16, 2024 · Open, Classified
Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.
Apr 16, 2024 · Open, Classified
Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.
Apr 16, 2024 · Open, Classified
Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.
Apr 16, 2024 · Open, Classified
Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.
Apr 16, 2024 · Open, Classified
Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.
Evidence
Related research
Citations indexed from PubMed.
Keep exploring
Related devices in CRM
CAPSUREFIX Novus
MEDTRONIC, INC. · 46,344 reports
Sprint Quattro Secure S MRI SureScan
MEDTRONIC, INC. · 39,133 reports
EMBLEM S-ICD
BOSTON SCIENTIFIC CORPORATION · 39,062 reports
CapSureFix Novus MRI SureScan
MEDTRONIC, INC. · 29,710 reports
Durata
ABBOTT (ST. JUDE MEDICAL) · 20,458 reports
Quadra Assura MP
ABBOTT (ST. JUDE MEDICAL) · 10,671 reports
Want automated safety signal detection?
Claripulse monitors these devices weekly and detects anomalies using 6 statistical methods — spike, trend, changepoint, peer-outlier, and more.
Get Early AccessUnderstanding this data