INOGEN MINI ICD DR Adverse Events: FDA MAUDE Data
BOSTON SCIENTIFIC CORPORATION · Implantable Cardioverter Defibrillator (ICD) · First cleared Apr 2014 · 2 device variants grouped
Total Reports
134
Reports (30d)
0
Active Signals
0
Open Recalls
12
Regulatory
FDA recalls for this device
Aug 20, 2025 · Open, Classified
Software to enhance Safety Architecture is available and designed to prevent initiation of Safety Mode in an ambulatory setting due to a high battery impedance state for the ACCOLADE family of devices which includes ACCOLADE, PROPONENT, ESSENTIO, and ALTRUA 2 dual chamber (DR) standard life (SL) and DR extended life (EL) pacemakers; and VISIONIST and VALITUDE cardiac resynchronization therapy pacemakers (CRT-Ps).
Jul 24, 2025 · Open, Classified
Affected lead models may experience gradually rising LVSI measurements in association with calcification of the defibrillation lead coils. The issue may lead to early lead replacement. Most serious harm is death or need for cardiac resuscitation.
Nov 30, 2023 · Open, Classified
The software application on the Programmer/Recorder/Monitor (PRM) for Implantable Pulse Generators will display certain diagnostic dates incorrectly, with a year in the 1990s.
Jul 11, 2023 · Open, Classified
There is a potential for a rare interaction between the EMBLEM S-ICD and LATITUDE communicator, which may cause S-ICD sensing disablement for a 24-hour interval.
Jul 11, 2023 · Open, Classified
There is a potential for a rare interaction between the EMBLEM S-ICD and LATITUDE communicator, which may cause S-ICD sensing disablement for a 24-hour interval.
Feb 2, 2023 · Open, Classified
Under specific circumstances, the U.S. product registration system did not send up enablement requests to U.S. LATITUDE Customer Support during an 8-month interval in 2022. For these patients, the HeartLogic Index and any associated Yellow Alerts are currently not visible in LATITUDE as may have been intended by the healthcare provider..
Evidence
Related research
Citations indexed from PubMed.
Keep exploring
Related devices in CRM
CAPSUREFIX Novus
MEDTRONIC, INC. · 46,344 reports
Sprint Quattro Secure S MRI SureScan
MEDTRONIC, INC. · 39,133 reports
EMBLEM S-ICD
BOSTON SCIENTIFIC CORPORATION · 39,062 reports
CapSureFix Novus MRI SureScan
MEDTRONIC, INC. · 29,710 reports
Durata
ABBOTT (ST. JUDE MEDICAL) · 20,458 reports
Quadra Assura MP
ABBOTT (ST. JUDE MEDICAL) · 10,671 reports
Want automated safety signal detection?
Claripulse monitors these devices weekly and detects anomalies using 6 statistical methods — spike, trend, changepoint, peer-outlier, and more.
Get Early AccessUnderstanding this data