Sprint Quattro MRI SureScan Adverse Events: FDA MAUDE Data

MEDTRONIC, INC. · Implantable Cardioverter Defibrillator (ICD), Permanent Defibrillator Electrode (Lead) · First cleared Jan 2016 · 2 device variants grouped

Total Reports

212

Reports (30d)

7

Active Signals

0

Open Recalls

83

Monthly Report Volume
Event Type Breakdown
Embed this chart in your article

Free to use with the source line. The chart updates weekly.

What the reports describe · Claripulse analysis

Most commonly reported problems

1

High Right Ventricular Capture Threshold

lead exhibited, right ventricular, use right, ventricular lead, capture

1

reports

2

Lead Integrity Alert with Fracture and Threshold Rise

integrity alert, lead integrity, alert lia, lia, integrity

1

reports

3

Lead Reprogrammed, Remains in Use

adverse, lead explanted, reprogramming, effects, additional adverse

1

reports

4

Short-Interval Noise Oversensing on Ventricular Lead

lead exhibited, right ventricular, use, ventricular lead, oversensing

1

reports

5

Ventricular Undersensing Delays Arrhythmia Therapy

ventricular fibrillation, undersensing, patient complications, ventricular lead, result event

1

reports

Problem groupings are generated by Claripulse from report narrative text. They summarize what reporters wrote, not adjudicated root cause.

Regulatory

FDA recalls for this device

Class II

Sep 17, 2026 · Open, Classified

Affected leads require additional engineering evaluation due to complaints regarding difficulty in achieving fixation during implantation. Potential harm of tissue trauma due to implant difficulty.

Class II

Oct 29, 2025 · Open, Classified

There is a potential for delayed time to high-voltage (HV) therapy should a rare sequence of events occur.

Class II

Apr 16, 2024 · Open, Classified

Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.

Class II

Apr 16, 2024 · Open, Classified

Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.

Class II

Apr 16, 2024 · Open, Classified

Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.

Class II

Apr 16, 2024 · Open, Classified

Potential for manufacturing defect. Weld crack led to devices failing at the leak check step in manufacturing.

Want automated safety signal detection?