Unify Assura Adverse Events: FDA MAUDE Data
ABBOTT (ST. JUDE MEDICAL) · CRT-Defibrillator (CRT-D) · First cleared Apr 2018 · 7 device variants grouped
Total Reports
4,710
Reports (30d)
16
Active Signals
0
Open Recalls
2
What the reports describe · Claripulse analysis
Most commonly reported problems
Remote Monitoring Oversensing Episodes
merlin net, net review, presented remotely, net, remotely merlin
11
reports
Post-Paced T-Wave Oversensing Observed
oversensing, contacted recommended, implantable cardioverter, observed device, support contacted
8
reports
Inappropriate Shock Delivered by ICD
implantable cardioverter, icd, shock, cardioverter defibrillator, defibrillator icd
6
reports
Patient Death with Unknown Cause
lead explanted, right, lead, patient implantable, defibrillator icd
5
reports
Dislodged Left Ventricular Lead
left, lead, replaced, left ventricular, ventricular lead
4
reports
Device Oversensing Observed During Follow-Up
observed device, support contacted, patient stable, technical support, device technical
4
reports
Problem groupings are generated by Claripulse from report narrative text. They summarize what reporters wrote, not adjudicated root cause.
Regulatory
FDA recalls for this device
Aug 16, 2023 · Open, Classified
Due to Bluetooth malfunction on a subset of Implantable Cardioverter Defibrillator (ICD) and Cardia Resynchronization Therapy Defibrillator *CRT-D) devices that were manufactured prior to April 2022 as a result of crystal component issue within the Bluetooth Low Energy (BLE) circuit. This results in the device entering an inductive telemetry only mode with loss of Bluetooth communication. In some instances, thought BLE communication is unavailable, the circuit may remain in a state which draws excessive power affecting battery longevity.
Mar 10, 2022 · Open, Classified
Due to a programmer software anomaly under very specific circumstance when executing a pacing capture Decrement Test in-clinic on implantable cardioverter and cardiac resynchronization therapy defibrillator devices, the programmer may continue to execute the Decrement Test instead of terminating the test and restoring the permanent programmed pacing parameters.
Evidence
Related research
Citations indexed from PubMed.
Keep exploring
Related devices in CRM
CAPSUREFIX Novus
MEDTRONIC, INC. · 46,089 reports
EMBLEM S-ICD
BOSTON SCIENTIFIC CORPORATION · 38,723 reports
Sprint Quattro Secure S MRI SureScan
MEDTRONIC, INC. · 38,006 reports
CapSureFix Novus MRI SureScan
MEDTRONIC, INC. · 29,057 reports
Durata
ABBOTT (ST. JUDE MEDICAL) · 20,299 reports
Quadra Assura MP
ABBOTT (ST. JUDE MEDICAL) · 10,625 reports
Want automated safety signal detection?
Claripulse monitors these devices weekly and detects anomalies using 6 statistical methods — spike, trend, changepoint, peer-outlier, and more.