ClaripulseClaripulse
MAUDE LookupResourcesBlog
LoginGet Early Access
ClaripulseClaripulse

Product

MAUDE LookupDashboard

Guides

FDA MAUDE DatabasePost-Market SurveillanceSignal Detection

Learn

BlogResourcesWhy Claripulse?

Legal

Privacy PolicyTerms of Service

This system analyzes publicly available FDA MAUDE data. It does NOT provide medical advice. MAUDE data is de-identified — do not attempt re-identification. © 2026 Claripulse.

Back to Cardiac Rhythm Management
MAUDE LookupCardiac Rhythm ManagementVALITUDE X4 CRT-P

VALITUDE X4 CRT-P Adverse Events: FDA MAUDE Data

BOSTON SCIENTIFIC CORPORATION · CRT-Pacemaker (CRT-P) · First cleared Jan 2004

Total Reports

1,805

Reports (30d)

79

Active Signals

1

Open Recalls

17

Monthly Report Volume
Event Type Breakdown

What the reports describe · Claripulse analysis

Most commonly reported problems

1

False Positive Battery Replacement Indicator

exhibited alert, indicator, monitoring disabled, message indicating, alert message

25

reports

2

Voltage Low Code with Replacement Recommendation

projected remaining, recorded code, voltage low, low projected, remaining capacity

20

reports

3

High Impedance Battery Analysis Request

reported request, impedance battery, battery device, potential high, device recorded

19

reports

4

Safety Mode Status Leading to Explantation

device explanted, subsequently, additional adverse, explanted replaced, safety mode

19

reports

5

Voltage Alert Triggered by Battery Condition

identified voltage, voltage alert, condition device, battery condition, alert triggered

14

reports

6

Battery Capacity Data Analysis Request

capacity reported, reported request, battery device, analyzed data, device recorded

14

reports

Problem groupings are generated by Claripulse from report narrative text. They summarize what reporters wrote, not adjudicated root cause.

Detection

Active safety signals

Disproportionate reportinghigh

Regulatory

FDA recalls for this device

Class I

Mar 19, 2026 · Open, Classified

Updated software, Brady software maintenance release 6 (SMR6), is now available for the ACCOLADE" family of pacemakers and cardiac resynchronization therapy pacemakers (CRT-Ps)1 and the advisory population is expanding to include all CRT-P and dual-chamber extended life (DR-EL) devices. Dual chamber modes are specifically indicated for treatment of the following: " Conduction disorders that require restoration of AV synchrony, including varying degrees of AV block " VVI intolerance (i.e., pacemaker syndrome) in the presence of persistent sinus rhythm " Low cardiac output or congestive heart failure secondary to bradycardia

Class I

Aug 20, 2025 · Open, Classified

Software to enhance Safety Architecture is available and designed to prevent initiation of Safety Mode in an ambulatory setting due to a high battery impedance state for the ACCOLADE family of devices which includes ACCOLADE, PROPONENT, ESSENTIO, and ALTRUA 2 dual chamber (DR) standard life (SL) and DR extended life (EL) pacemakers; and VISIONIST and VALITUDE cardiac resynchronization therapy pacemakers (CRT-Ps).

Class I

Aug 20, 2025 · Open, Classified

Software to enhance Safety Architecture is available and designed to prevent initiation of Safety Mode in an ambulatory setting due to a high battery impedance state for the ACCOLADE family of devices which includes ACCOLADE, PROPONENT, ESSENTIO, and ALTRUA 2 dual chamber (DR) standard life (SL) and DR extended life (EL) pacemakers; and VISIONIST and VALITUDE cardiac resynchronization therapy pacemakers (CRT-Ps).

Class I

Aug 20, 2025 · Open, Classified

Software to enhance Safety Architecture is available and designed to prevent initiation of Safety Mode in an ambulatory setting due to a high battery impedance state for the ACCOLADE family of devices which includes ACCOLADE, PROPONENT, ESSENTIO, and ALTRUA 2 dual chamber (DR) standard life (SL) and DR extended life (EL) pacemakers; and VISIONIST and VALITUDE cardiac resynchronization therapy pacemakers (CRT-Ps).

Class I

Aug 20, 2025 · Open, Classified

Software to enhance Safety Architecture is available and designed to prevent initiation of Safety Mode in an ambulatory setting due to a high battery impedance state for the ACCOLADE family of devices which includes ACCOLADE, PROPONENT, ESSENTIO, and ALTRUA 2 dual chamber (DR) standard life (SL) and DR extended life (EL) pacemakers; and VISIONIST and VALITUDE cardiac resynchronization therapy pacemakers (CRT-Ps).

Class I

Aug 20, 2025 · Open, Classified

Software to enhance Safety Architecture is available and designed to prevent initiation of Safety Mode in an ambulatory setting due to a high battery impedance state for the ACCOLADE family of devices which includes ACCOLADE, PROPONENT, ESSENTIO, and ALTRUA 2 dual chamber (DR) standard life (SL) and DR extended life (EL) pacemakers; and VISIONIST and VALITUDE cardiac resynchronization therapy pacemakers (CRT-Ps).

Keep exploring

Related devices in CRM

CAPSUREFIX Novus

MEDTRONIC, INC. · 43,528 reports

→

EMBLEM S-ICD

BOSTON SCIENTIFIC CORPORATION · 36,855 reports

→

Sprint Quattro Secure S MRI SureScan

MEDTRONIC, INC. · 36,335 reports

→

CapSureFix Novus MRI SureScan

MEDTRONIC, INC. · 27,017 reports

→

Durata

ABBOTT (ST. JUDE MEDICAL) · 19,619 reports

→

Quadra Assura MP

ABBOTT (ST. JUDE MEDICAL) · 10,450 reports

→

Want automated safety signal detection?

Claripulse monitors these devices weekly and detects anomalies using 6 statistical methods — spike, trend, changepoint, peer-outlier, and more. 1 active signal detected right now.

Get Early Access

Understanding this data

What FDA MAUDE data does and does not tell you

How these reports are filed, why raw counts mislead, and the limits to know before drawing conclusions.

→

How a safety signal is detected

What the "Active Signals" count above means and the methods that separate a real signal from noise.

→
Disclaimer: This system analyzes publicly available FDA MAUDE data. It does NOT provide medical advice. MAUDE data is de-identified. Do not attempt re-identification. Report counts may differ from the FDA's MAUDE search due to processing cadence and deduplication. Data is updated weekly.